Second Generation PULS (Packed Ultrasonic Level Sensor) Oil Level Sensor; Recording the liquid level (static and dynamic)
Second Generation PULS (Packed Ultrasonic Level Sensor) Oil Level Sensor; Recording the liquid level (static and dynamic)
PULS Oil Level Sensor
Customer Benefits
TECHNICAL DATA | |
Operating voltage (for oil level measurement) | 9 – 16 V |
Operating voltage (for temperature measurement) | 6 – 16 V |
Reverse-polarity voltage | - 14 V / 60 s |
Overvoltage | 15 s at 28 V 250 ms at 32 V |
Measurement range (static and dynamic) | 18 – 118.8 mm |
Operating temperature | - 40°C to + 160°C |
Operating temperature (for oil level measurement)1) | - 10°C to + 150°C |
Reheating temperature | max. 5.700 h at 125°C max. 240 h at 145°C max. 60 h at 160°C |
Storage temperature | - 40°C to + 150°C |
Current consumption | 4 mA |
Max. current consumption during measuring | 50 mA |
Protocol²) | PWM (open collector, lowside) |
Mating connector³) | Kostal no. 09 44 13 82 |
IP rating | IP 6K9K, IP6K4 |
Weight | 76 g ± 3 % |
Applicability on fluids4) | Hydraulic, transmission, and engine oils |
Viscosities | 1 mm2/s to 1.300 mm2/s |
Accuracy of temperature measurement | |
between 60°C and 120°C | ± 2 K |
At - 40°C up to 60°C and 120°C to 160°C |
± 3 K |
Accuracy of level measurement | |
At -10°C to 30°C | ± 4 mm |
At 30°C to 150°C | ± 2 mm |
PULS Oil Level Sensor | 6PR 010 497-501 |